Mixed volume of material:
Mixer power:
Features
1. Operation Temperature: 1100℃ (1200℃ for short time).
2. Maximum energy efficiency is achieved by surrounding the chamber with thermal-efficient alumina fiber ceramic insulation.
3. Heavy duty double layer structure with cooling fan. Lower temperature in outside case.
4. PID automatic control via current limiting phase angle fired the resistor, e.g. SCR (Silicon Controlled Rectifier).
5. Power control with 51 segments programmable.
Ⅰ. Technical Specifications | |
Chamber size | 200x200x200mm(width*height*depth)(8Liter) |
Max. temperature | 1200 C (<2hour) |
Working temperature | 1100 C |
Temperature controlling | PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, |
current limiting resistor. | |
30 programmable segments for precise control of heating rate, cooling rate and dwell time. |
|
Built in PID Auto-Tune function with overheating & broken thermocouple broken protection. |
|
Over temperature protection and alarm allows for operation without attendant. |
|
Temperature accuracy | ±1C |
Temperature Uniformity | ±5C over 120mm @ 1100C |
±3C over 80mm @ 1100C | |
Heating rate | 0-20C /min |
Thermocouple | K type with 99.7% purity Alumina tube |
Heating element | Quality heating wire |
Furnace Chamber | Two layers of ceramic fiber insulation materials |
First layer: 1430°C ceramic fiber board, density 450kgs/m3. Thermal conductivity (1200℃) |
|
is only 0.18W/m.k. | |
Second layer: 1260°C ceramic fiber board, density 350kgs/m3. | |
Furnace structure | Double layer steel casing with dual cooling fan, surface temperature below 60oC |
Furnace door | Front-side open |
Power cutting off when furnace door open | |
Working voltage | 220V, 50HZ |
Rated power | 5KW |
Warranty | One year limited warranty with life time support. (Consumable parts such as heating elements |
and crucibles are not covered by the warranty, please order the replacement at related products) |
|
ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the |
|
coverage of One Year Limited Warranty. | |
Certifications | CE |
Ⅱ. Application Notes | |
Using Attentions | Cooling rate shall also not exceed 10℃ /min. |
Toxic or explosive gases are not recommended for use with this furnace without necessary. |
|
safety controls and supervision. | |
Small cracks may appear on the surface of the refractory ceramics over extended use. |
|
This is a normal occurrence and the cracks may be repaired with alumina coating. |
|
Stander chamber size (mm) |
Refractory door block must be inserted before closing door. |
100x100x100 120x120x130 150x150x150 150x150x200 | |
200x200x200 200x200x300 250x250x300 300x300x300 | |
300x300x400 350x350x500 400x400x400 450x450x450 | |
500x500x500 600x600x600 800x800x800 900x900x900 |